Key Points for Start-up Operation of Medium Frequency Electric Furnace
1) Close the switch of the incoming low-voltage switch frame, check whether the indications of three-phase incoming line voltage and ammeter are normal, and adjust the power regulating potentiometer to the minimum value;
2) Press the control power ON button, after 2 to 3 seconds press “Main Circuit ON Button”, then press “Inverter Start Button”, the medium frequency power supply will start working. At this time, the DC voltmeter, ammeter, medium frequency frequency meter and power meter will all have indications;
3) After successful start-up, slowly adjust the power knob to the required power position to input power; If the medium frequency is not established (i.e. start-up fails), press the “Inverter Stop” button to reset it, then press “Inverter Start” again to restart.
Abnormal start-up of medium frequency electric furnace may be caused by many factors. When this problem occurs, you can troubleshoot step by step according to the following steps:
1. First confirm that both the power switch and control switch have been turned on;
2. Check whether there is any alarm after turning on the control power supply and eliminate the fault in time;
3. Check whether the medium frequency transformer has open circuit, inter-turn short circuit or poor contact;
4. The ratio of medium frequency voltage to DC voltage, namely the β angle, is too small, so the β angle should be increased appropriately.
5. Check whether the inverter KK thyristor and rectifier KP thyristor are damaged:
6. Check whether the heating capacitor is broken down:
7. Check whether the water-cooled cable has open circuit or short circuit:
8. Check whether there is foreign metal between the turns of the induction coil of the medium frequency furnace body, which causes inter-turn short circuit;
9. Check whether the furnace lining has problems such as breakout, poor insulation and electric leakage.
Notes for Shutdown Operation of Medium Frequency Electric Furnace
1) When shutting down the medium frequency electric furnace, first turn the power regulating knob to a lower position, then press the “Inverter Stop” button.
2) If a long-term shutdown is required, press “Inverter Stop” first, then press the main circuit OFF button, and finally press the “Control Power OFF” button. (The above steps cannot be operated in reverse order!) At this time, you can turn off the internal circulating cooling water of the medium frequency power supply and heating capacitor (which refers to stopping the operation of the circulating water pump of this system), while the internal and external circulating systems of the furnace body can only stop the pump and cut off water supply after the surface temperature of the furnace lining drops below 100℃ (generally it takes 72 hours).
3) In winter, when stopping cooling water supply, it is necessary to consider the problem that frozen water in the pipeline will crack the water pipe (methods such as heat preservation, draining all remaining water, adding ethylene glycol can be adopted).