Email: Address: Shuangxi West Road, Luoxin Industrial Zone, Xin'an County, Luoyang City

Analysis of the Causes of Thyristor Burnout

📅 2018-05-11 15:12:32 ✍️ Author:admin 👁️ 1622 views
Ready
1.6x

During the operation of medium frequency furnaces, phenomena such as thyristor burnout frequently occur, which is often a thorny problem for maintenance personnel, and sometimes the fault cannot be resolved. Based on years of medium frequency furnace maintenance records, we have sorted out the information below for maintenance personnel's reference.

1. Water cut-off in the water cooling jacket of inverter thyristor or reduced heat dissipation effect —— Replace the water cooling jacket. Sometimes the water output and pressure of the water cooling jacket seem sufficient, but due to water quality issues, a layer of scale often adheres to the inner wall of the water cooling jacket. Scale is a substance with extremely poor thermal conductivity. Even though sufficient water flows through, the heat dissipation effect is greatly reduced due to the heat insulation of scale. The judgment method is: Run the equipment at a power significantly lower than the overcurrent value for about ten minutes, shut down quickly, and immediately touch the core of the thyristor element by hand. If it feels burning hot, the fault is caused by this reason.

2. Poor contact or broken wire of the tank circuit connecting conductor —— Check the tank circuit connecting conductor, and deal with it according to actual conditions. When there is poor contact or broken wire in the tank circuit connecting conductor, arcing will occur after the power rises to a certain value, which affects the normal operation of the equipment and thus triggers the equipment's protection action. Sometimes arcing will generate instantaneous overvoltage across both ends of the thyristor. If the overvoltage protection acts too late, the thyristor element will be burned out. This phenomenon often causes both overvoltage protection and overcurrent protection to act at the same time.

3. The instantaneous spike voltage of the reverse voltage borne by the thyristor during reverse turn-off is too high —— In the main circuit of a medium frequency power supply, instantaneous reverse spike voltage is absorbed by the resistance-capacitance (RC) absorption circuit. If the resistor or capacitor in the absorption circuit is open-circuited, the instantaneous reverse spike voltage will be too high and burn out the thyristor. After power off, use a multimeter to measure the resistance of the absorption resistor and the capacitance of the absorption capacitor to determine whether the RC absorption circuit is faulty.

4. Reduced load-to-ground insulation —— The reduced insulation of the load circuit causes arcing between the load and the ground, which interferes with the trigger time of the pulse or forms high voltage across both ends of the thyristor, and finally burns out the thyristor element.

5. Fault in pulse trigger circuit —— If the trigger pulse is suddenly lost during equipment operation, it will cause inverter open circuit, generate high voltage at the output end of the medium frequency power supply, and burn out the thyristor element. This fault is generally caused by faults in the inverter pulse formation and output circuit, which can be checked with an oscilloscope. It may also result from poor contact of the inverter pulse lead, you can shake the wire connector by hand to locate the fault.

6. Load open circuit during equipment operation —— When the equipment is running at high power, if the load suddenly becomes open-circuited, high voltage will be formed at the output end and burn out the thyristor element.

7. Load short circuit during equipment operation —— When the equipment is running at high power, if the load is suddenly short-circuited, there will be a huge short-circuit current impact on the thyristor. If the overcurrent protection acts too late to provide protection, the thyristor element will be burned out.

8. Fault in protection system (protection failure) —— The safe operation of thyristors is mainly guaranteed by the protection system. If the protection system fails, even a minor abnormality of the equipment will endanger the safety of the thyristor. Therefore, when the thyristor is burned out, inspection of the protection system is essential.

9. Thyristor cooling system fault —— The thyristor generates a large amount of heat during operation, and cooling is required to ensure its normal operation. Generally, there are two cooling methods for thyristors: one is water cooling, and the other is air cooling. Water cooling is widely used, while air cooling is generally only used for power equipment below 100KW. Medium-frequency equipment that adopts water cooling is usually equipped with water pressure protection circuits, but basically all these circuits only protect the main water inlet, and cannot trigger protection if water blockage occurs in any single water branch.

10. Reactor fault —— Internal arcing inside the reactor causes intermittent current on the inverter side.